Cooling Capacity: | 15kw | Heating Capacity: | 24kw |
---|---|---|---|
Air Flow: | 1600CFM | Motor Type: | AC Motor |
Display Type: | Digital Display | Water Pump: | Build In Water Pump |
Electrical Box: | Outside/build In Optional | Fresh Air Hole: | Standard Available |
Power Supply: | 110/220V 1Ph 50/60Hz | Certification: | CE, ISO, Rohs |
Modbus: | Optional | Auto Restart: | Optional |
Finger Protect: | Finger Protect Grill Optional | Drain Tray: | Extra Bigger Drain Tray Optional |
High Light: | chilled water ceiling cassette fan coil unit,cassette type fcu |
Four way cassette fan coil unit 4TR capacity 1600CFM, build in water pump and electrical box water fan coil unit
Cassette fan coil units is widely used in hotels, restaurants, factories, hospitals, exhibition galleries, shopping malls and moving buildings.It is used to meet the requirements of cooling, dehumidifier, heating and so on.
1. Available in 52 different models. AC motor and BLDC motor, 2 pipe system and 4 pipe system.
2. Centrifugal fan, driven by a three-speed motor, statically and dynamically balanced, low noise.
3. Air flow direction can be changed to have uniform cooling.
4. No need for air duct.Easy for installation.
5. Special design of the air filter, washable for many times.
6. Easy for cleaning and maintenance .
7. Driving device and remote control device can be provided for the outlet plates.
8. Water drain pump build in design.
9. Compact design, suitable for strict space installation.
10. Luxury shape and ABS panel. External and internal sound and heat insulation
Specifications for hydronic four way cassette fan coil model MFP-34KM-MK1:
1. Air flow 1400CFM, 1600CMH
2. Cooling capacity 4TR, 15w
3. Heating capacty 7TR, 24Kw
4. Two pipe/tube system
5. With build in water pump
6. Power supply 220V-1-50Hz
7. Cassette Fan coil unit Panel size 1050x1050mm
Cassette Type FCU | Model No. | ||
2pipe system | MFP-272KM4-MK4 | 220V-1-50Hz | |
Cooling Capacity | |||
Testing item | Capacity-W | At Fan speed | Air Volume CMH |
Total Capacity 【w】 | 15000 | High Speed | 2720 |
Sensible Capacity【w】 |
11970 |
||
Total Capacity 【w】 | 12968 | Medium Speed | 2300 |
Sensible Capacity【w】 | 8925 | ||
Total Capacity 【w】 | 11550 | Low Speed | 1730 |
Sensible Capacity【w】 | 7245 | ||
Heating Capacity | |||
Testing item | Capacity-W | At Fan speed | Air Volume CMH |
Total Capacity 【w】 | 24000 | High Speed | 2720 |
Total Capacity 【w】 | 18375 | Medium Speed | 2300 |
Total Capacity 【w】 | 15750 | Low Speed | 1730 |
Entering air temperature | Cooling Mode | Entering air temperature2 | Heating Mode |
Dry ball Temp 【℃】 | 27.0 | Dry ball Temp 【℃】 | 20 |
Wet ball Temp 【℃】 | 19.5 | ||
Inlet water temp 【℃】 | 7.0 | Inlet water temp 【℃】 | 50 |
Outlet water temp 【℃】 | 12.0 | Outlet water temp 【℃】 | 40 |
Item | data | Item2 | Data2 |
Rated Power input 【 w】 | 40.0 | Unit dimension L【mm】 | 592 |
waterflow volume 【m3/h】 | 0.34 | Unit dimension W【mm】 | 592 |
water pressure dropping 【kPa】 | 11.0 | Unit dimension H【mm】 | 242 |
Connection pipe Dia【Inch】 | ZG3/4" | Panel dimension L【mm】 | 650 |
Static pressure【Pa】 | 0.0 | Panel dimension W【mm】 | 650 |
Water drain pipe Dia 【mm】 | ¢26 | Panel dimension H【mm】 | 40 |
Packing data | |||
Unit dimension L【mm】 |
1080 |
Panel dimension L【mm】 | 1110 |
Unit dimension W【mm】 | 1080 | Panel dimension W【mm】 | 1110 |
Unit dimension H【mm】 | 335 | Panel dimension H【mm】 | 80 |
Operating limits Water inlet temperature: 5-80°C. Room air temperature: 6-40°C. Relative humidity: 15-75%. Maximum exchanger pressure: 800 kPa (81,5 mc.a.). Power supply voltage: 230 V ±10%. |
Full ranges of capacities we have for M style cassette fan coil unit 2 pipe systems:
MODEL Casstte fan coil unit 4 pipe system |
air volume | COOLING CAPACITY | HEATING CAPACITY | POWER INPUT |
m3/h | W | W | W | |
MFP-34KM-Q1M | 380 | 2000 | 3100 | 40 |
MFP-51KM-Q1M | 550 | 3000 | 4700 | 50 |
MFP-68KM-Q1M | 680 | 3800 | 5900 | 58 |
MFP-80KM-Q1M | 780 | 4200 | 6500 | 60 |
MFP-85KM-Q1M | 880 | 4900 | 7600 | 70 |
MFP-102KM-Q1M | 1050 | 5800 | 9000 | 95 |
MFP-130KM-Q1M | 1300 | 7000 | 10900 | 125 |
MFP-136KM-Q1M | 1380 | 7500 | 11600 | 130 |
MFP-153KM-Q1M | 1550 | 8100 | 12200 | 145 |
MFP-170KM-Q1M | 1750 | 9800 | 15200 | 160 |
MFP-204KM-Q1M | 2050 | 11000 | 17100 | 190 |
MFP-238KM-Q1M | 2200 | 12000 | 18600 | 210 |
MFP-272KM-Q1M | 2720 | 15000 | 24000 | 230 |
Full ranges of capacities we have for M style cassette fan coil unit 4 pipe systems:
MODEL Casstte fan coil unit 4 pipe system | air volume | COOLING CAPACITY | HEATING CAPACITY | POWER INPUT |
m3/h | W | W | W | |
MFP-34KM4-Q1MM1 | 360 | 1950 | 1950 | 40 |
MFP-51KM4-Q1MM1 | 520 | 2950 | 3000 | 50 |
MFP-68KM4-Q1MM1 | 650 | 3700 | 3750 | 58 |
MFP-80KM4-Q1MM1 | 740 | 4100 | 4150 | 60 |
MFP-85KM4-Q1MM2 | 840 | 4800 | 4850 | 70 |
MFP-102KM4-Q1MM2 | 1000 | 5700 | 5750 | 95 |
MFP-130KM4-Q1MM2 | 1240 | 6850 | 6950 | 125 |
MFP-136KM4-Q1MM3 | 1320 | 7350 | 7400 | 130 |
MFP-153KM4-Q1MM3 | 1480 | 7940 | 7780 | 145 |
MFP-170KM4-Q1MM3 | 1660 | 9600 | 9700 | 160 |
MFP-204KM4-Q1MM3 | 1950 | 10800 | 10900 | 190 |
MFP-238KM4-Q1MM3 | 2090 | 11750 | 11850 | 210 |
MFP-272KM4-Q1MM4 | 2090 | 13200 | 13500 | 210 |
Testing condition:
2-tube system | 4-tube system |
Cooling Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC Entering/out water temperature: 7ºC/ 12℃ |
Cooling Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC Entering/out water temperature: 7ºC/ 12ºC |
Heating Entering air temperature: 20ºC Entering water temperature: 60ºC, Same water flow rate as for the cooling |
Heating Entering air temperature: 20ºC Entering/out water temperature: 60ºC/ 50ºC |
Notes:
1. Both AC or BLDC motor available.
2. Both 50HZ or 60HZ power supplies available.
As we all know Hydronic cassette units are ideal for applications and modernizations with suspended ceilings. Ceiling cassette fan coil units make each served area an independent controlled temperature zone to suit diverse requirements. Such as hotels, offices, restaurant, shopping mall applications,etc.
MECO start to produce the first cassette fan coil unit in 2001, and Cassette fan coil unit always a hard point for us.
After nearly 20 years’ experience accumulation, we have completely models of M style cassette fan coil unit and BLDC motor type cassette fan coil unit. The M style cassette fan coil unit is our core competitiveness which has high stability and comprehensive functions.
Certifications for MECO cassette fan coil units:
fan motor | P.C.B | reciever Board | sensor |
trans former |
fan motor capacitor | remote controller | wire controller | drain pump | water level switch | fan | drain tray | swing motor | drain pipe | panel | filter | corner board of panel |
FAQ.
Q:Can you make OEM brand orders water fan coil unit?
A: Yes of course. As a specialized manufacturer and exporter for fan coil units in China, we sincerely hope to establish business relations with your esteemed corporation. Now we do OEM/ODM for a lot of famous brands in China and other countries, such as YORK, CIAC, KingAir, QingHuaTongFang,TCL,AUX,CHIGO,LS,etc.
Q: How long is your warranty for your fan coil unit?
A: We offer 18 months warranty for our fan coil units products. We offer 1% free repair parts and professional technical support.
Q: Our hotel want to choose the fan coil unit which have 4 pipe system, do you have this one?
A: Yes, Most of our fan coil unit products have 4 pipe system as optional.
Q: Do you have selection software for your Fan coil unit?
A: Not yet now. But we can select the water fan coil units for you based on your given selection request.
LEAVE US A MESSAGE
With reliable quality and outstanding performance, MECO products are successfully sold to more than 30 countries and regions including: Europe; South America; Middle east; Southeast Asia and Africa etc.